User Guide
OmniAccess 6000: Installation Guide
40 Part 031639-00 May 2005
Communication settings for the console port are specified in Tab l e 6 - 4 :
.
Serial Port Adapter
You can adapt a DB-9 male terminal port for the required RS-232 serial cable
using the included adapter. Pin-outs are show in Figure 6-3:
FIGURE 6-3 Serial Port Adapter
T
ABLE 6-4 Console Terminal Settings
Baud Rate Data Bits Parity Stop Bits Flow Control
9600 8 None 1 None
CAUTION—Do not connect Access Points to the serial console port.
The serial port is designed to connect to RS-232-only devices.
Non-RS-232 devices such as Access Points will cause the Switch to
fail and can cause damage.
3
4
5
2
5
63
RJ-45 DB-9
Internal
Connections
TxD
GND
RxD
1
2
3
4
5
6
7
8
TxD
TGND
RGND
RxD
RJ-45 Female
Pin-Out
Direction
Input
Output
DB-9 Female
Pin-Out
TxD
RxD
Ground
5
4
3
2
1
9
8
7
6
Direction
Input
Output