30 Part 031639-00 May 2005
Verify that the maximum power load does not exceed the capacity of your
electrical circuits.
Inserting a Power Supply
Verify you understand the procedure and all precautions.
Before beginning, read the entire procedure. Verify you understand all the
precautions in these steps as well as those on page 6.
Select a power supply slot for the power supply.
z
The 200 W power supply (OWA-6000-PS200) can be installed in power
supply slots 1 and 3 only.
z The 400 W power supply (OWA-6000-PS400) can be installed in any power
supply slot:
FIGURE 5-2 Alcatel 6000-series Power Supply Slots
T
ABLE 5-6 Maximum Load using 400 W Power Supplies
Component Description Power
x
Factor
=
Power
Subtotal
Total power required (from worksheet on
page 27)
W x 1.25
safety
=
400 W Power Supply
(OWA-6000-PS400) overhead
26 W x units =
Maximum power load in Watts:
CAUTION—This procedure should be performed by a trained technician.
1
2