User Guide

OmniAccess 6000: Installation Guide
26 Part 031639-00 May 2005
Indicator LEDs
Air Intake Vent
This air intake vent helps the internal fan cool the power supply during
operation. To prevent blockage, keep all material at least 10 cm (4 inches) from
the vent.
Power Cord Retaining Clip (optional 400 W OWA-6000-PS400 only)
This clip fits over the power cord once the plug has been inserted into the
power input socket. It helps prevent the power cord from being pulled out
accidentally.
TABLE 5-1 200 W Power Supply LEDs
LED Name Position State Description
Over
Temp.
Protection
Top Off Power supply temperature is okay.
Amber Power supply fan has failed or
temperature is too high.
DC Okay
Middle Green DC power output is okay.
Off DC power output is not within
tolerance.
AC Okay
Bottom Green AC power input is okay.
Off AC power input is not within tolerance.
TABLE 5-2 400 W Power Supply LEDs
LED Name Position State Description
Over
Temp.
Protection
Top Off Power supply temperature is okay.
Red Power supply fan has failed or
temperature is too high.
DC Okay
Middle Green DC power output is okay.
Red DC power output is not within
tolerance.
AC Okay
Bottom Green AC power input is okay.
Red AC power input is not within tolerance.
3
4
5