User Guide
OmniAccess 6000 400W PSU Installation Notes: Installation Guide
4 Part 031655-00 May 2005
5. Attach the power cord to the power supply.
Plug an appropriate power cord into the power input socket. The socket
accepts a power cord with a standard IEC320 plug.
6. Attach the power cord to a proper electrical outlet.
Make sure that your site’s electrical systems can handle the switch’s power
load.
Each power supply (
OAW-6000-PS400) is rated at 400 W total and is
auto-ranging to accept 85 to 264 VAC, at 50 to 60 Hz.
Depending on the switch’s total power load, you may be required to increase
the capacity of your site’s electrical systems. Refer to the installation guide for
information on maximum power load, use of a UPS, and the like.
CAUTION—For proper safety and performance, the power cord must be
rated to 10 A and conform to grounded electrical standards in the
country where the product is operated.