User's Manual
Table Of Contents
- 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide
- 1 Preface
- Table of contents
- List of figures
- List of tables
- 2 ETSI ONT safety guidelines
- 3 ETSI environmental and CRoHS guidelines
- 4 ANSI ONT safety guidelines
- 5 XS-240W-A and XS-250WX-A unit data sheet
- 5.1 XS-240W-A and XS-250WX-A part numbers and identification
- 5.2 XS-240W-A and XS-250WX-A general description
- 5.3 XS-240W-A and XS-250WX-A software and installation feature support
- 5.4 XS-240W-A and XS-250WX-A interfaces and interface capacity
- 5.5 XS-240W-A and XS-250WX-A LEDs
- 5.6 XS-240W-A and XS-250WX-A detailed specifications
- 5.7 XS-240W-A and XS-250WX-A GEM ports and T-CONTs
- 5.8 XS-240W-A and XS-250WX-A performance monitoring statistics
- 5.9 XS-240W-A and XS-250WX-A functional blocks
- 5.10 XS-240W-A and XS-250WX-A standards compliance
- 5.11 XS-240W-A and XS-250WX-A special considerations
- 6 Install an XS-240W-A or XS-250WX-A indoor ONT
- 7 Replace an XS-240W-A or XS-250WX-A indoor ONT
- 8 Configure an XS-240W-A or XS-250WX-A indoor ONT
- Customer document and product support
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Install an XS-240W-A or XS-250WX-A indoor ONT
Issue: 01 Edition 01 67
6.6 Procedure
Use this procedure to install an XS-240W-A or XS-250WX-A indoor ONT.
1 Place the indoor ONT unit:
a On the flat surface, such as a desk; go to step 3.
b On a wall, go to step 2.
2 Mount the XS-240W-A or XS-250WX-A indoor ONT on a wall.
Note 1 — Observe the local and national laws and regulations
that may be applicable to this installation.
Note 2 — Observe the following:
• The indoor ONT should be installed in accordance with the
applicable requirements of the NEC or CEC. Local
authorities and practices take precedent when there is
conflict between the local standard and the NEC or CEC.
• The indoor ONT must be installed by qualified service
personnel.
• Indoor ONTs must be installed with cables that are suitably
rated and listed for indoor use.
• See the detailed specifications in the XS-240W-A and
XS-250WX-A unit data sheet for the temperature ranges for
these ONTs.
Note — The XS-240W-A or XS-250WX-A cannot be stacked with
another ONT or with other equipment. The ONT mounting requirements
are:
• allow a minimum 100 mm clearance above the top cover
• allow a minimum 50 mm clearance from the side vents
• do not place any heat source directly above the top cover or below the
bottom cover
R05.06.00 | March 2017 | 3FE 46861 AAAA TCZZA | Edition 01