User's Manual
Table Of Contents
- 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide
- 1 Preface
- Table of contents
- List of figures
- List of tables
- 2 ETSI ONT safety guidelines
- 3 ETSI environmental and CRoHS guidelines
- 4 ANSI ONT safety guidelines
- 5 XS-240W-A and XS-250WX-A unit data sheet
- 5.1 XS-240W-A and XS-250WX-A part numbers and identification
- 5.2 XS-240W-A and XS-250WX-A general description
- 5.3 XS-240W-A and XS-250WX-A software and installation feature support
- 5.4 XS-240W-A and XS-250WX-A interfaces and interface capacity
- 5.5 XS-240W-A and XS-250WX-A LEDs
- 5.6 XS-240W-A and XS-250WX-A detailed specifications
- 5.7 XS-240W-A and XS-250WX-A GEM ports and T-CONTs
- 5.8 XS-240W-A and XS-250WX-A performance monitoring statistics
- 5.9 XS-240W-A and XS-250WX-A functional blocks
- 5.10 XS-240W-A and XS-250WX-A standards compliance
- 5.11 XS-240W-A and XS-250WX-A special considerations
- 6 Install an XS-240W-A or XS-250WX-A indoor ONT
- 7 Replace an XS-240W-A or XS-250WX-A indoor ONT
- 8 Configure an XS-240W-A or XS-250WX-A indoor ONT
- Customer document and product support
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
XS-240W-A and XS-250WX-A unit data sheet
Issue: 01 Edition 01 53
Note
(1)
The primary path for the earth ground for these ONTs is provided by the 12V Return signal in the power
connector.
5.5 XS-240W-A and XS-250WX-A LEDs
Figure 18 shows the XS-240W-A and XS-250WX-A indoor ONT LEDs.
UPS power supply This connection supports the UPS power adapter described in Table 5.
Power input This connection is provided through the power connector. A power cable fitted with a
barrel connector is used to make the connection.
On/Off button This button turns the ONT on or off.
Reset button Pressing the Reset button for less than 10 seconds reboots the ONT; pressing the
Reset button for 10 seconds resets the ONT to the factory defaults, except for the
LOID and SLID.
LED button This button turns the LEDs on or off.
WLAN button Wi-Fi service is compliant with IEEE 802.11 standards and is enabled and disabled
using the WLAN button.
WPS buttons The Wi-Fi Protected Setup buttons are labeled WPS2.4G and WPS5G. These buttons
enable and disable WLAN data encryption.
USB ports This connection is provided through 2 USB 3.0 ports. The ONT supports external USB
hard drives that can be made accessible to all LAN devices.
The following rates apply to the USB 3.0 ports:
• Rate current: 900mA
• Maximum continuous current: 1.5A
• Typical short-circuit current: 2.3A
Connection
(1)
Description
(2 of 2)
R05.06.00 | March 2017 | 3FE 46861 AAAA TCZZA | Edition 01