User's Manual

Table Of Contents
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Issue: 01 Edition 01 111
Procedure 24 TR-069 configuration
1 Select Network > TR-069 from the top-level menu in the 10G PON Gateway window, as
shown in Figure 44.
Figure 44 TR-069 network window
Table 34 describes the fields in the TR-069 network window.
Table 34 TR-069 network parameters
2 Configure TR-069 by entering the required information.
Field Description
Periodic Inform Enable Select this checkbox to enable periodic inform updates
Periodic Inform Interval(s) Time between periodic inform updates, in seconds
URL URL of the auto-configuration server
Username Username used to log in to the auto-configuration server
Password Password used to log in to the auto-configuration server
Connect Request Username Username used to log in to the ONT
Connect Request Password Password used to log in to the ONT