User's Manual
Table Of Contents
4 — Configure a G-241W-A indoor ONT
4-10 Alcatel-Lucent 7368 ISAM ONT
Edition 01
I-240W-S I-241W-S I-241W-U Product Guide
Procedure 4-7 Optics module status retrieval
1 Select Status > Optics Module Status from the top-level menu in the GPON Home
Gateway window, as shown in Figure 4-7.
Figure 4-7 Optics module status window
Table 4-6 describes the fields in the Optics module status window.
Table 4-6 Optics module status parameters
2 Click Refresh to update the displayed information.
3 STOP. This procedure is complete.
Field Description
Laser Bias Current (ONT ANI-ONT-Side Optical
Measurements)
Laser bias current, measured in uA
Optics Module Voltage (ONT ANI-ONT-Side Optical
Measurements)
Optics module voltage, measured in V
Optics Module Temperature (ONT ANI-ONT-Side
Optical Measurements)
Optics module temperature, measured in
C
Rx Optics Signal Level at 1490 nm (ONT ANI-ONT-Side
Optical Measurements)
Received optics signal level at 1490 nm,
measured in dBm
Tx Optics Signal Level at 1310 nm (ONT ANI-ONT-Side
Optical Measurements)
Transmitted optics signal level at 1310 nm,
measured in dBm
Lower (ONT ANI-ONT-Side Optical
Measurements-Optical Threshold)
Lower optical threshold, measured in dBm
Upper (ONT ANI-ONT-Side Optical
Measurements-Optical Threshold)
Lower optical threshold, measured in dBm