User's Manual

R05.07.00 | September 2017 | Edition 02
7368 ISAM ONT G-240W-F Product Guide
Replace a G-240W-F indoor ONT
Issue: 01
3FE-47087-AAAA-TCZZA
79
16
If used, configure the SLID; see the 7368 ISAM ONT Configuration, Management, and
Troubleshooting Guide for more information.
Note A new SLID or the old SLID may be used with the replacement
ONT. If a new SLID is used, the new SLID must also be programmed at
the P-OLT using TL1 or a network manager. If the old SLID is used, no
changes need to be made at the P-OLT; see the operations and
maintenance documentation for the OLT for more details.
17
Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and
Cabling Installation Guide.
18
Activate and test the services; see the 7368 Hardware and Cabling Installation Guide.
19
If necessary, reset the ONT.
i
Locate the Reset button on the side of the G-240W-F indoor ONT as shown in
Figure 25.
ii
Insert the end of a straightened paper clip or other narrow object into the hole in the
Reset button to reset the ONT.
20
STOP. This procedure is complete.