User's Manual
R05.07.00 | September 2017 | Edition 02
7368 ISAM ONT G-240W-F Product Guide
Replace a G-240W-F indoor ONT
Issue: 01
3FE-47087-AAAA-TCZZA
75
7.6 Procedure
Use this procedure to replace a G-240W-F indoor ONT.
1
Deactivate the ONT services at the P-OLT.
If you are using the SLID feature, this step is not required. The ONT and the services can
remain in service (IS).
i
Use the RTRV-ONT command to verify the ONT status and th associated services.
Record the serial number or the SLID of the ONT displayed in the command output.
Example:
RTRV-ONT::ONT-1-1-1-1-1;
ii
If the ONT is in service, place the ONT in OOS state.
Example:
ED-ONT::ONT-1-1-1-1-1::OOS;
2
If used, disable the Wi-Fi service by pressing the WLAN button; see Figure 25 for the location
of the WLAN button on the side of the ONT.
Figure 25 G-240W-F indoor ONT Reset, LED, WLAN, and WPS buttons
(side)
Connections (back)
Antenna
Antenna
Fiber cover
US B 1 US B 2 LA N 1 LA N 2 LA N 3 LA N 4 TE L 1 T EL 2
POWER ON/OFF
ON/OFF
buttons (side):
Wall
mounting
hole
RESET
LED
WLAN
WPS
LEDs (front)
Wall
mounting
hole
26033
3
Power down the unit by using the on/off power switch; see Figure 26 for the location of the
power switch.
RE S ET
LE D
WL AN