Install a G-240W-F indoor ONT
70
3FE-47087-AAAA-TCZZA
Issue: 01
4
Connect the Ethernet cables to the RJ-45 ports; see Figure 22 for the location of the RJ-45
ports.
5
Route the POTS cables directly to the RJ-11 ports as per local practices.
The POTS port to the left is labeled 1 for Line 1 while the port on the right is labeled 2 for Line
2, as shown in Figure 22.
6
Connect the fiber optic cable with SC/APC adapter into the SC/APC connector on the bottom
of the ONT; see Figure 23 for the location of the SC/APC connector.
Danger Fiber cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning Be careful to maintain a bend radius of no less than 1.5 in.
(3.8 cm) when connecting the fiber optic cable. Too small of a bend radius
in the cable can result in damage to the optic fiber.
Note Fiber cable preparation varies depending on the type and size
of the inside or outside plant fiber cable being spliced to the SC/APC
(SC/UPC) fiber optic pigtail cable.
7
Install the power supply according to manufacturer specifications.
Note Observe the following:
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 1.25 A.
8
Connect the power cable to the power connector.
9
Power up the ONT unit by using the power on/off switch.
10
If used, enable the Wi-Fi service.
i
Locate the WLAN button on the side of the ONT; see Figure 23 for location of the WLAN
button.
ii
Press the WLAN button to change the status of the Wi-Fi service.