User's Manual

R05.07.00 | September 2017 | Edition 02
7368 ISAM ONT G-240W-F Product Guide
Configure a G-240W-F indoor ONT
Issue: 01
3FE-47087-AAAA-TCZZA
145
2
Click Refresh to update the displayed information.
3
STOP. This procedure is complete.
Procedure 53 Optics module status retrieval
1
Select Status > Optics Module Status from the top-level menu in the SFU GPON Home
Gateway window, as shown in Figure 75.
Figure 75 Optics module status window
Table
50 describes the fields in the Optics module status window.
Table 50 Optics module status parameters
Field
Description
Laser Bias Current (ONT ANI-ONT-Side Optical
Measurements)
Laser bias current, measured in uA
Optics Module Voltage (ONT ANI-ONT-Side Optical
Measurements)
Optics module voltage, measured in V
Optics Module Temperature (ONT ANI-ONT-Side
Optical Measurements)
Optics module temperature, measured in C
Rx Optics Signal Level at 1490 nm (ONT
ANI-ONT-Side Optical Measurements)
Received optics signal level at 1490 nm, measured
in dBm
Tx Optics Signal Level at 1310 nm (ONT
ANI-ONT-Side Optical Measurements)
Transmitted optics signal level at 1310 nm,
measured in dBm
(1 of 2)