User's Guide
Table Of Contents
- 7368 ISAM ONT G-240W-F Product Guide
- 1 Preface
- Table of contents
- List of figures
- List of tables
- 2 ETSI ONT safety guidelines
- 3 ETSI environmental and CRoHS guidelines
- 4 ANSI ONT safety guidelines
- 5 G-240W-F unit data sheet
- 5.1 G-240W-F part numbers and identification
- 5.2 G-240W-F general description
- 5.3 G-240W-F software and installation feature support
- 5.4 G-240W-F interfaces and interface capacity
- 5.5 G-240W-F LEDs
- 5.6 G-240W-F detailed specifications
- 5.7 G-240W-F GEM ports and T-CONTs
- 5.8 G-240W-F performance monitoring statistics
- 5.9 G-240W-F functional blocks
- 5.10 G-240W-F standards compliance
- 5.11 G-240W-F special considerations
- 6 Install a G-240W-F indoor ONT
- 7 Replace a G-240W-F indoor ONT
- 8 Configure a G-240W-F indoor ONT
- 9 ONT configuration file over OMCI
- Customer document and product support
G-240W-F unit data sheet
58
7368 ISAM ONT G-240W-F Product Guide
Edition 01 Issue: 01
Table 9 G-240W-F indoor ONT environmental specifications
5.7 G-240W-F GEM ports and T-CONTs
Table 10 lists the maximum number of supported T-CONTs and GEM ports.
Table 10 G-240W-F indoor ONT capacity for GEM ports and T-CONTs
5.8 G-240W-F performance monitoring statistics
The following section identifies the supported performance monitoring statistics for
G-240W-F ONTs. A check mark indicates the statistic is supported on that ONT. An
empty cell indicates the statistic is not supported. The following tables are
categorized by supported alarm types:
• Table 11 provides statistics for ONTENET type counters
• Table 12 provides statistics for ONTL2UNI type counters
• Table 13 provides statistics for PONONTTC, PONONTMCTC, PONONTTCHSI,
PONONTTCCES, PONONTTCFLOW, and PONONTTCVOIP type counters
• Table 14 provides statistics for PONONTTC aggregate type counters
Temperature range and humidity Altitude
Operating: 23°F to 113 F (-5°C to 45°C) ambient temperature
5% to 95% relative humidity, non-condensing
Contact your Nokia technical support
representative for more information
Storage: -4°F to 158°F (-20°C to 70C)
GEM ports or TCONTs Maximum Notes
GEM ports per indoor or outdoor ONT 256 254 are present; 122 are available, and 2 are
reserved for multicast and debugging
T-CONTs per indoor or outdoor ONT 32 32 are present; 31 are available, and 1 is reserved
for OMCI
Note — If you have trouble accessing G-240W-F ONTs
performance monitoring statistics using TL1, please contact
your Nokia support representative for more information about
how to access and retrieve performance monitoring type
counters.
DRAFT