User's Guide

Table Of Contents
G-240W-F unit data sheet
58
7368 ISAM ONT G-240W-F Product Guide
Edition 01 Issue: 01
Table 9 G-240W-F indoor ONT environmental specifications
5.7 G-240W-F GEM ports and T-CONTs
Table 10 lists the maximum number of supported T-CONTs and GEM ports.
Table 10 G-240W-F indoor ONT capacity for GEM ports and T-CONTs
5.8 G-240W-F performance monitoring statistics
The following section identifies the supported performance monitoring statistics for
G-240W-F ONTs. A check mark indicates the statistic is supported on that ONT. An
empty cell indicates the statistic is not supported. The following tables are
categorized by supported alarm types:
Table 11 provides statistics for ONTENET type counters
Table 12 provides statistics for ONTL2UNI type counters
Table 13 provides statistics for PONONTTC, PONONTMCTC, PONONTTCHSI,
PONONTTCCES, PONONTTCFLOW, and PONONTTCVOIP type counters
Table 14 provides statistics for PONONTTC aggregate type counters
Temperature range and humidity Altitude
Operating: 23°F to 113 F (-5°C to 45°C) ambient temperature
5% to 95% relative humidity, non-condensing
Contact your Nokia technical support
representative for more information
Storage: -4°F to 158°F (-20°C to 70C)
GEM ports or TCONTs Maximum Notes
GEM ports per indoor or outdoor ONT 256 254 are present; 122 are available, and 2 are
reserved for multicast and debugging
T-CONTs per indoor or outdoor ONT 32 32 are present; 31 are available, and 1 is reserved
for OMCI
Note — If you have trouble accessing G-240W-F ONTs
performance monitoring statistics using TL1, please contact
your Nokia support representative for more information about
how to access and retrieve performance monitoring type
counters.
DRAFT