User's Guide
Table Of Contents
- 7368 ISAM ONT G-240W-F Product Guide
- 1 Preface
- Table of contents
- List of figures
- List of tables
- 2 ETSI ONT safety guidelines
- 3 ETSI environmental and CRoHS guidelines
- 4 ANSI ONT safety guidelines
- 5 G-240W-F unit data sheet
- 5.1 G-240W-F part numbers and identification
- 5.2 G-240W-F general description
- 5.3 G-240W-F software and installation feature support
- 5.4 G-240W-F interfaces and interface capacity
- 5.5 G-240W-F LEDs
- 5.6 G-240W-F detailed specifications
- 5.7 G-240W-F GEM ports and T-CONTs
- 5.8 G-240W-F performance monitoring statistics
- 5.9 G-240W-F functional blocks
- 5.10 G-240W-F standards compliance
- 5.11 G-240W-F special considerations
- 6 Install a G-240W-F indoor ONT
- 7 Replace a G-240W-F indoor ONT
- 8 Configure a G-240W-F indoor ONT
- 9 ONT configuration file over OMCI
- Customer document and product support
G-240W-F unit data sheet
48
7368 ISAM ONT G-240W-F Product Guide
Edition 01 Issue: 01
•
2.4 GHz wireless interface
• 2 5dBI indoor multi-directional external WiFi antenna (not detachable)
• MIMO
• support for up to 20 concurrent wireless connections
• 802.11b/g/n compliant
• MDI/MDIX auto sensing
• auto-negotiation for speed and duplex
• multiple voice Codec
• echo cancellation
• Analog Telephone Adapter (ATA) function integrated based on SIP (RFC3261)
and H.248, with various CLASS services supported, including Caller ID, Call
Waiting, Call Forwarding, and Call Transfer
• auto reconnect when connection to server is lost
• Network Address Translation (NAT)
• 3 REN per line
5.2.1 TR-069 support
The ONT supports the reading of optical parameters via TR-069:
• laser bias current
• voltage
• temperature
• received signal levels
• lower thresholds
These are the same optical parameters supported in the GUI. For more information,
see Table 21 in the chapter “Configure a G-240W-F indoor ONT”.
The ONT supports the status retrieval and configuration of the following Wi-Fi
parameters via TR-069:
• channel
• SSID
• password for WPA and WEP
• Tx power (transmission rate in dBm)
These are the same TR-069 object parameters that are supported in the GUI. For
more information, see Tables 17 and 26 in the chapter “Configure a G-240W-F
indoor ONT”.
The ONT also supports TR-069 statistics and troubleshooting for LAN, WAN, and
WiFi.