User's Manual

Table Of Contents
1 — G-240W-A unit data sheet
Alcatel-Lucent 7368 ISAM ONT 1-11
Edition 02
G-240W-A Product Guide
Table 1-6 G-240W-A indoor ONT power consumption specifications
Table 1-7 lists the environmental specifications for G-240W-A indoor ONT.
Table 1-7 G-240W-A indoor ONT environmental specifications
1.7 G-240W-A GEM ports and T-CONTs
Table 1-8 lists the maximum number of supported T-CONTs and GEM ports. See the
appropriate release Customer Release Notes for the most accurate list of supported
devices.
Table 1-8 G-240W-A indoor ONT capacity for GEM ports and T-CONTs
1.8 G-240W-A performance monitoring statistics
The following section identifies the supported performance monitoring statistics for
G-240W-A ONTs. A check mark indicates the statistic is supported on that ONT. An
empty cell indicates the statistic is not supported. The following tables are
categorized by supported alarm types:
Table 1-9 provides statistics for ONTENET type counters
Table 1-10 provides statistics for ONTL2UNI type counters
Mnemonic Maximum power
(Not to exceed)
Condition Minimum power Condition
G-240W-A
(3FE 56525
AAAA)
18 W 2 POTS off-hook, 4
10/100/1000 Base-T
Ethernet, Wi-Fi operational
5.9 W 2 POTS on-hook, other
interfaces/services not
provisioned
Mounting method Temperature range and humidity Altitude
On desk or wall
mounted
Operating: 32°F to 113°F (0°C to 45°C) ambient
temperature
10% to 90% relative humidity, non-condensing
Contact your Alcatel-Lucent technical support
representative for more information
Storage: Contact your Alcatel-Lucent support
representative for more information
ONT or MDU Maximum Notes
Package P ONTs
GEM ports per indoor or
outdoor ONT
124 124 are present; 122 are available, and 2 are
reserved for multicast and debugging
T-CONTs per indoor or outdoor
ONT
32 32 are present; 31 are available, and 1 is
reserved for OMCI
R05.02.01 | October 2015 | 3FE-45360-AAAA-TCZZA | Edition 02