User's Manual
Table Of Contents
- 7368 ISAM ONT G-120W-F Product Guide
- 1 Preface
- Table of contents
- List of figures
- List of tables
- 2 ETSI ONT safety guidelines
- 3 ETSI environmental and CRoHS guidelines
- 4 ANSI ONT safety guidelines
- 5 G-120W-F unit data sheet
- 5.1 G-120W-F part numbers and identification
- 5.2 G-120W-F general description
- 5.3 G-120W-F software and installation feature support
- 5.4 G-120W-F interfaces and interface capacity
- 5.5 G-120W-F LEDs
- 5.6 G-120W-F detailed specifications
- 5.7 G-120W-F GEM ports and T-CONTs
- 5.8 G-120W-F performance monitoring statistics
- 5.9 G-120W-F functional blocks
- 5.10 G-120W-F standards compliance
- 5.11 G-120W-F special considerations
- 6 Install a G-120W-F indoor ONT
- 7 Replace a G-120W-F indoor ONT
- 8 Configure a G-120W-F indoor ONT
- 9 ONT configuration file over OMCI
- Customer document and product support
7368 ISAM ONT G-120W-F Product Guide Install a G-120W-F indoor ONT
Issue: 01 3FE-46922-AAAA-TCZZA 69
7 Install the power supply according to manufacturer specifications.
8 Connect the power cable to the power connector.
9 Power up the ONT unit by using the power on/off switch.
10 If used, enable the Wi-Fi service by pressing the WLAN button.
11 If used, enable the WPS by pressing the WPS button.
12 Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and
Cabling Installation Guide.
13 Activate and test the services; see the 7368 Hardware and Cabling Installation Guide.
14 If used, configure the SLID; see the 7368 ISAM ONT Configuration, Management, and
Troubleshooting Guide.
15 If necessary, reset the ONT.
i Locate the Reset button on the back of the G-120W-F indoor ONT as shown in
Figure 22.
ii Insert the end of a straightened paper clip or other narrow object into the hole in the
Reset button to reset the ONT.
16 STOP. This procedure is complete.
Note — Fiber cable preparation varies depending on the type and size
of the inside or outside plant fiber cable being spliced to the SC/APC
(SC/UPC) fiber optic pigtail cable.
Note — Observe the following:
• Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 1.25 A.
R05.06.01 | June 2017 | Edition 01