User's Guide

54 3FE-46615-AAAA-TCZZA Issue: 01
Replace an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide
7.5 Safety information
Read the following safety information before replacing the unit.
Danger 1 — Hazardous electrical voltages and currents can
cause serious physical harm or death. Always use insulated
tools and follow proper safety precautions when connecting or
disconnecting power circuits.
Danger 2 — Make sure all sources of power are turned off and
have no live voltages present on feed lines or terminals. Use a
voltmeter to measure for voltage before proceeding.
Danger 3 — Always contact the local utility company before
connecting the enclosure to the utilities.
Caution — Keep indoor CPEs out of direct sunlight. Prolonged
exposure to direct sunlight can damage the unit.
Note 1 — Observe the local and national laws and regulations
that may be applicable to this installation.
Note 2 — Observe the following:
The CPE should be installed in accordance with the
applicable requirements of the NEC or CEC. Local
authorities and practices take precedent when there is
conflict between the local standard and the NEC or CEC.
The CPE must be installed by qualified service personnel.
Indoor CPEs must be installed with cables that are suitably
rated and listed for indoor use.
See the detailed specifications in the A-240Z-A unit data
sheet for the CPE temperature ranges for these CPEs.
7.6 Procedure
Use this procedure to replace an A-240Z-A CPE.
1
Deactivate the CPE services at the P-OLT.
i
Use the RTRV-CPE command to verify the CPE status and th associated services.
Record the serial number of the CPE displayed in the command output.
Example: