User's Guide

7368 ISAM CPE
A
-240Z-
A
Product Guide
A
-240Z-
A
unit data sheet
Issue: 01 3FE-46615-AAAA-TCZZA 41
5.4.1
A-240Z-A connections and components
Figure 7 shows the physical connections for A-240Z-A CPEs.
Figure 7 A-240Z-A CPE physical connections
ON/OFF TEL1 TEL2 WAN LAN1 LAN2 LAN3 LAN4 USB USB UPS LED
POWER
ON/OFF
button
TEL1 and TEL2
POTS ports
(RJ-11)
WAN port
(RJ-45)
LAN ports (4)
(RJ-45)
USB 2.0
ports (2)
Power supply
connector
LED on/off
button
Power
connector
Reset
button
26018
Table 6 describes the physical connections for A-240Z-A CPEs.
Table 6 A-240Z-A CPE physical connections
Connection
(1)
Description
On/Off button This button turns the CPE on or off.
POTS ports
This connection is provided through RJ-11 ports. Up to two POTS connections are
supported.The POTS ports support voice services.
WAN port This connection is provided through an RJ-45 GE interface.
Ethernet ports (LAN)
This connection is provided through Ethernet RJ-45 connectors. Up to four
10/100/1000 Base-T Ethernet interfaces are supported.The Ethernet ports can
support both data and in-band video services on all four interfaces.
USB ports
This connection is provided through 2 USB 2.0 ports. The maximum combined
current is 1000mA. The throughput for each port is 90 Mbps. The CPE supports
external USB hard drives that can be made accessible to all LAN devices.
UPS (power supply) input This connection is provided through a UPS connector.
LED ON/Off button This button is used to turn all LEDs on or off.
Reset button
Pressing the Reset button for less than 10 seconds reboots the CPE; pressing the
Reset button for 10 seconds resets the CPE to the factory defaults, except for the
LOID and SLID.
Power input
This connection is provided through the power connector. A power cable fitted with
a barrel connector is used to make the connection.
Note
(1)
The primary path for the earth ground for these CPEs is provided by the 12V Return signal in the power
connector.