Specifications

65
you set, it stops the auto-store operation.
Setting the Modulation Type
SRCH/CLOCALL OPT E
SET MODULATION
E
This setting controls the modulation type used for quick
search and Close Call operations.
Select your setting, then press E.
AUTO Uses the default setting for the current frequency
AM Uses AM (amplitude modulation)
FM Uses FM (frequency modulation)
NFM Uses narrow band FM
Setting Attenuation
SRCH/CLOCALL OPT E
SET ATTENUATOR
E
This setting controls the attenuator for quick search, service
search and Close Call operation.
Select your setting, then press E.
OFF The attenuator is off.
ON Reception is attenuated by about 18 dB.
Note: Turn on this setting if you are near other strong signal
sources. Using the attenuator sometimes helps to reduce
interference and desensitization that strong signals create.
Setting Data Skip
SRCH/CLOCALL OPT
E
SET DATA SKIP
E
This setting controls how the scanner behaves when it
detects a constant-level transmission during quick search or
Close Call operation.
Select your setting, then press E.
OFF The scanner remains on the transmission until it ends.
ON The scanner quickly resumes searching or Close Call
operation.
Notes: