Technical data

Rev. 9/27/2009 Manual #001451 30
Operation
High Speed Doors
UltraSmart™ STARTUP PROCEDURE
Albany’s UltraSmart™ control system is designed to accommodate numer-
ous option modules and future technological advances. This manual will
address necessary settings for the standard options; however, optional
modules and special applications may require additional steps to be taken
for proper setup. Refer to the control schematic shipped inside the panel
enclosure for additional electrical and setup details.
1) Press and hold until ―LIMIT SETUP‖ is shown on the display; Press
2) ―CLOSED LIMIT‖ should be displayed; Press
3) Use and/or to bring the door to the full closed position; Press
4) Press ―FULL OPEN LIMIT‖ should be displayed; Press
5) Use and/or to bring the door to the full open position; Press
6) Press ―PARTIAL OPEN LIMIT‖ should be displayed; Press
7) Use and/or to bring the door to the partial open position or set the
same as the full open position if not used; Press
8) Press until ―DOOR READY‖ is displayed
SETTING DOOR LIMITS
NOTE: SAFETY DEVICES WILL PREVENT THE DOOR FROM CLOSING IF ACTIVATED DURING
SETUP
ENABLE THE WIRELESS SYSTEM (IF EQUIPPED) PRIOR TO SETTING DOOR LIMITS