Owner`s manual
8
1. Lay the head assembly on its back on the floor in a
clean area in front of the door opening.
2. Slide each side column onto the head assembly.
Install the two 1/2” flat washers, lock washers, and
1/2”x1” bolts in each bracket.
3. Using a safe lifting device, carefully lift the entire
door assembly up to a vertical position against the
door jambs.
MOUNTING ULTRALITE AND LOW PROFILE DOORS
4. Position the side columns with the inside face of the
black mounting brackets set 3/4” out from the door
jamb on each side. Ensure the columns are plumb
and mark or temporarily fasten the mounting brack-
ets to the wall.
5. Disconnect the side columns from the mounting
brackets by removing the 2 bolts in each bracket.
6. Move the columns off the wall. Prepare the holes
and permanently anchor the mounting brackets as
needed. These brackets could also be welded to a
steel jamb.
7. Reattach the side columns to the mounting brackets
using the 2 bolts removed from each bracket earlier.
8. Install the head seals to the wall as shown below.
9. Caulk door jambs to seal the opening when finished.
The head assembly is heavy. Use proper lifting de-
vices and techniques to securely and safely lift the
head assembly. Failure to properly secure the head
assembly could result in death or serious injury.