Owner`s manual

19
Periodic Maintenance
Albany Door Systems high speed doors are engineered for low maintenance operation. The door should be visually inspected daily
for wear and tear, and operated to verify functions. Quarterly maintenance should be performed to clean components and to check all
safety functions and check for mechanical and electrical integrity.
Daily Inspection
1. Inspect the door fabric for wear or damage.
2. Operate the door through several openings and closings. Verify that the door seats against the floor and that the door fabric re-
mains tight and does not wrinkle. Verify that the door opens fully, slightly beyond the wall opening, and does not open too far.
If the door does not seat against the floor properly or opens to the wrong position, refer to “Setting Door Limit Adjust-
ments”.
If the door fabric has diagonal wrinkles the door fabric roll at the top of the door is not level and perpendicular to the
side rails. Leveling adjustments should be made as soon as possible to prevent wear or damage. Refer to the installation
instructions or contact Albany Door Systems.
3. With the door closing, place an object through the light curtain, or photoeyes, on each side of the door. Verify that the door stops
immediately.
4. If a multiple panel door is installed, check at each end of the ribs to verify that they are in place and centered.
5. Inspect the coiled electrical wire for wear or damage.
6. Check the light curtain slots for dirt or dust accumulation and clean as necessary.
7. While the door is closing, tap the bottom of the door edge wand verify that the door stops and reverses to a fully open position.
Do not stand under the door when performing the following inspection. If the bottom bar reversing switch is not functioning
correctly injury can occur.