System information
Example
# ppupdate k.img standby (Installation starts.)
Software update start
Current version is 10.2
New version is 10.2.A (The version of the software is
displayed.)
Update done.
# (Update is complete.)
09/19 22:41:22 E5 MSU 01300438 2314:0b0600000000 Fatal error detected on other
system. This system (MSU1) is active. (The standby system restarts.)
#
09/19 22:41:22 E3 MSU 01300412 2314:1b0100000000 System status changed from
duplex to simplex.
#
09/19 22:41:58 E3 SOFTWARE 01300462 1001:14e800000000 There is mismatch between
active and standby software version.
#
09/19 22:41:01 E3 MSU 01300413 2314:09a
9
00000000 System status changed from
simplex to duplex.
#
18) In a BCU, CSU, or MSU redundant configuration, execute the show system command to
confirm that the status of the standby system is standby.
Example
> show system
Date 20XX/09/19 22:40:36 UTC
System: AX6304S, OS-SE Ver. 10.2.A
Node : Name=
Contact=
Locate=
Elapsed time : 00:00:31
Machine ID : 0012.e220.5300
Device redundancy cpu status : duplex
Power control : normal
Power redundancy-mode : check is not executed
PS1 = active
PS2 = active
PS3 = active
PS4 = active
Fan : active No = FAN1(1), FAN1(2), FAN1(3),
FAN2(4), FAN2(5), FAN2(6)
Speed=normal
MSU1 : standby (The status of the standby system is displayed.)
:
:
Go to step 20).
22