System information

9) Exec
ute the reload no-dump-image command to restart the Switch.
Example
BOOT-INST-OS# reload no-dump-image
Restart OK? (y/n): y (Enter y.)
10) After login: is displayed, log in with the user name operator.
11) Execute the show logging command to make sure that the abbreviated name and version
of the software running on the active system are correct.
In a BCU, CSU, or MSU redundant configuration, execute the show logging standby
command to make sure that the abbreviated name and version of the software running on the
standby system are correct.
Example
> show logging (Check the active system.)
Date 20XX/09/15 22:34:37 UTC
System information
AX6304S, OS-SE Ver. 10.2 (Build:158), MSU1(active) (Check the displayed information.)
Logging information
KEY 09/15 22:34:37 operator(tty00):> show logging
:
:
> show logging standby (Check the standby system.)
Date 20XX/09/15 22:34:44 UTC
System information
AX6304S, OS-SE Ver. 10.2 (Build:158), MSU2(standby) (Check the displayed information.)
Logging information
:
:
The installation procedure is complete.
12