Instruction manual
1. Components Overview
16
Name Type Status Description
SYSTEM1
LED: Green,
orange, or red
Indicates the Switch
status.
Green: Operation is possible.
Orange: A partial Switch failure was
detected.
Red: A Switch failure was detected.
SYSTEM2
LED: Green,
orange, or red
Indicate the status of the
power consumption
mode
#8#9
Green: Power saving mode.
Orange: Not supported.
Blinking green: The power consumption
mode is changing.
Red: Not supported.
Off: Normal power consumption mode.
LINK
LED: Green or
orange
Green: A link is established.
Orange: A failure has been detected.
Off: A link failure occurred
#6
or
operation has stopped.
#7
T/R LED: Green
Indicates the operation
status of the
MANAGEMENT port.
Green: A packet is being sent or
received.
Off: No packets are being sent or
received.
#1: A basic control unit can be turned off by the Inactivate operation from the system
operation panel or by entering a command from the operation terminal.
#2: The switch is recessed from the surface of the front panel. Use a screwdriver
with a small head to press it.
#3: If you press the switch for one second or less, the Switch might not be reset.
#4: After a restart, a login password and an administrator password are no longer
required. Be especially careful if you restart the unit with this method.
#5: The system can be switched only if you press the ACH switch on the basic
control unit of the active system.
#6: Cable disconnection is also included.
#7: You can stop operation by entering a command.
#8: This is supported by the software Ver. 11.1 or later. The LED is always turned off
because this is not supported by a version earlier than Ver. 11.1 of the software.
#9: The status of the power consumption mode is displayed only for the basic
control unit of the active system.
When pressing a switch, do not use anything with a fragile tip, or
anything that might become caught in the Switch, such as a pin or
paper clip. Doing so could result in fire or electric shock.