Instruction manual

MA-2 AX66S-H001X
12
4.9.2 Inserting and removing an SFP-T transceiver
During operation and when a link is being established, the temperature of the SFP-T
transceiver can rise to 65
o
C. Do not touch the SFP-T transceiver while it is operating
and just after it has stopped. Doing so could result in burns.
When you remove the SFP-T transceiver, use the procedure below. Failure to do so
could result in burns.
- To remove the SFP-T transceiver while the Switch is on, execute the inactive
command, and then wait 5 minutes before removing the SFP-T transceiver.
- To remove the SFP-T transceiver while the Switch is off, turn off the Switch, and
then wait 5 minutes before removing the SFP-T transceiver.
For details about the inactive command, see 17. Ethernet in the manual Software
Manual Operation Command Reference Vol. 1.
(1) Inserting an SFP-T transceiver
Keep the lever upright as shown in the figure, and insert the SFP transceiver until you hear a click.
Figure 4-41a Inserting an SFP transceiver (upper port)
(1) Lever
(2) SFP transceiver
(3) Ethernet port
The above figure shows an example of inserting an SFP transceiver into the upper
Ethernet port of the network interface unit.
If you want to insert an SFP transceiver in the lower Ethernet port, turn the SFP
transceiver upside down and install it as shown in the figure below.
(1)
(2)
(3)