Instruction manual

MA-2 AX63S-H001-50X
17
The description of (2) Installing a management and switching unit (step 6) has been corrected as follows.
Correction:
Step 6
Restore the operation information. Because the restoration procedure is different for the active system and the
standby system, make sure you perform the appropriate procedure.
6-1 Restoring the management and switching unit of the active system
1. Restore the operating information from the file you have backed up. (Use the restore command.) To
do this, use the backup file stored on a memory card or an ftp server.
If you cannot find the backed up software in the backup file, see the Software Update
Guide to install the software, and then execute the restore command.
For details about the restore command, see 9. Checking the Software Version and
Switch Status in the manual Software Manual Operation Command Reference Vol. 1.
BOOT INST OS is displayed on the system operation panel of the management and
switching unit if the software is not installed. When the software is installed, BOOT
I
NST
OS disappears.
6-2 Restoring the management and switching unit of the standby system
1. Install the software on the management and switching unit of the standby system. (Use the cd
command to move to the directory where the update file is stored, and then use the ppupdate
command. Initially, the update file is named k.img and is saved in the /usr/var/update
directory.)
2. Restart the management and switching unit of the standby system. (Use the reload standby
command.)
3. Synchronize the configuration, user account, password, and license key settings of the standby system
with the settings of the active system. (Use the synchronize command.)
4. When an optional license is installed, restart the management and switching unit of the standby system
in order to apply the license key information. (Use the reload standby command.)
If you cannot find the update file in /usr/var/update, see the Software Update
Guide to transfer the update file to the Switch, and then execute the ppupdate
command.
For details about the commands to be used, see the following manuals:
cd command: 4. Operating the Configuration and Files in the manual Software Manual
Operation Command Reference Vol. 1
ppupdate command: 14. Software Management in the manual Software Manual
Operation Command Reference Vol. 1
synchronize command: 10. BCU/CSU/MSU Redundancy in the manual Software
Manual Operation Command Reference Vol. 2
reload command: 9. Checking the Software Version and Switch Status in the manual
Software Manual Operation Command Reference Vol. 1
BOOT INST OS is displayed on the system operation panel of the management and
switching unit if the software is not installed. When the software is installed, BOOT INST
OS disappears.