Troubleshooting guide

3. Troubleshooting Functional Failures During Operation
148
4
notconnect The target BSU is not implemented. Make sure that as many BSU boards as the
number of active and standby BSUs (or the
number of active BSUs only, if standby BSUs
are not required) are implemented. If the
required number of boards is already
implemented, no action is required. If not
implemented, implement as many BSU boards
as required.
5
initialize The target BSU is being initialized. Wait until the initialization is complete.
6
disable no power enable is set by a
configuration command.
Make sure that the BSU board to use is
implemented, and set the power enable
configuration command to put the target BSU
into
active, standby hot, standby cold, or
standby cold2 status.
No. Operating
status of BSU
units
Cause Action