Instruction manual
2. Preparation for Installation
74
Table 2-2 General Installation Conditions for AX3630S Series Switches (AC, AC (PoE) or DC Power
Models)
*1 Excluding the dimensions of connectors.
*2 Weight of the main device only. The weight of cables, rack mounted brackets, memory cards and transceivers are excluded.
*3 The power supply cable bundled with the main device is only applicable to 100 V AC.
*4 Heat emission of the main device only.
Item
Model Name
AX3630S
-24T
AX3630S
-24T2X
AX3630S
-24P
AX3630S
-24TD
AX3630S
-24T2XD
Dimensions (W × D × H)
*1
445 × 380 × 43 mm 445 × 490 ×
43 mm
445 × 380 × 43 mm
Weight
*2
5 kg or less 8 kg or less 5 kg or less
Input
voltage
Rating Single phase 100 to 120 V AC, 200 to
240 V AC
*3
Single phase
100 to 120 V AC
-48 V DC
Variation
range
90 to 127.2 V AC, 180 to 254.4 V AC 90 to 127.2 V AC -40 to -57 V DC
Frequency 50/60 ± 1 Hz -
Maximum input current 0.8 A @ 100 V
AC
0.9 A @ 100 V
AC
5.8 A @ 100 V
AC
1.5 A @ -48 V DC 1.8 A @ -48 V DC
0.4 A @ 200 V
AC
0.5 A @ 200 V
AC
---
Maximum power
consumption
75 W 89 W 580 W 70 W 82 W
Maximum heat emission 270 kJ/h 321 kJ/h
757 kJ/h
*4