Instruction manual

2. Preparation for Installation
73
2.2 Installation Conditions
This section provides the conditions for installing the main device and an external power unit (EPU). The installation
environment must meet these conditions.
2.2.1 General Installation Conditions
The General Installation Conditions for the device are listed below.
Table 2-1 General Installation Conditions for AX2400S Series Switches (AC or DC Power Models)
*1 Excluding the dimensions of connectors.
*2 Weight of the main device only. The weight of cables, rack mounted brackets, memory cards and transceivers are excluded.
*3 The power supply cable bundled with the main device is only applicable to 100 V AC.
Item
Model Name
AX2430S
-24T
AX2430S
-24T2X
AX2430S
-48T
AX2430S
-48T2X
AX2430S
-24TD
AX2430S
-24T2XD
AX2430S
-48TD
Dimensions (W × D × H)
*1
445 × 380 × 43 mm
Weight
*2
5 kg or less 5.5 kg or less 5 kg or less 5.5 kg or
less
Input
voltage
Rating
Single phase 100 to 120 V AC, 200 to 240 V AC
*3
-48 V DC
Variation
range
90 to 127.2 V AC, 180 to 254.4 V AC -40 to -57 V DC
Frequency 50/60 ± 1 Hz -
Maximum input current 0.8 A
@ 100 V
AC
0.9 A
@ 100 V
AC
1.2 A
@ 100 V
AC
1.3 A
@ 100 V
AC
1.5 A
@ -48 V
DC
1.7 A
@ -48 V
DC
2.5 A
@ -48 V
DC
0.4 A
@ 200 V
AC
0.5 A
@ 200 V
AC
0.6 A
@ 200 V
AC
0.7 A
@ 200 V
AC
---
Maximum power
consumption
74 W 88 W 118 W 130 W 69 W 80 W 118 W
Maximum heat emission 267 kJ/h 317 kJ/h 425 kJ/h 468 kJ/h 249 kJ/h 288 kJ/h 425 kJ/h