Instruction manual

3. Preparation of Interface Cables and Terminals
98
3.1 Connecting Interface Cables and Terminals
The applicable interfaces for the devices and the cables to connect them are listed in Table 3-1 Interface Cables and
Terminal Connection Cables.
The user should provide these cables.
Table 3-1 Interface Cables and Terminal Connection Cables
Port/Slot Transceiver Interface Cable Connector
10/100/1000BASE-T
port
(PoE not supported)
- 10BASE-T UTP cable
(Category 3 or higher)
RJ45
connector
100BASE-TX UTP cable
(Category 5 or higher)
1000BASE-T UTP cable
(Enhanced Category 5 or higher)
10/100/1000BASE-T
port
(PoE supported)
- 10BASE-T UTP cable
(Category 5 or higher)
100BASE-TX UTP cable
(Category 5 or higher)
1000BASE-T UTP cable
(Enhanced Category 5 or higher)
SFP slot SFP-T (T)
(PoE not
supported)
10BASE-T UTP cable
(Category 5 or higher)
RJ45
connector
100BASE-TX
1000BASE-T UTP cable
(Enhanced Category 5 or higher)
SFP-SX (T) 1000BASE-SX Multiple-terminal mode optical fiber
(core/cladding diameter = 50 µm/125 µm)
LC duplex
connector
Multiple-terminal mode optical fiber
(core/cladding diameter = 62.5 µm/125 µm)
SFP-SX2 (T) 1000BASE-SX2 Multiple-terminal mode optical fiber
(core/cladding diameter = 50 µm/125 µm)
Multiple-terminal mode optical fiber
(core/cladding diameter = 62.5 µm/125 µm)
SFP-LX (T) 1000BASE-LX
Multiple-terminal mode optical fiber
*1
(core/cladding diameter = 50 µm/125 µm)
Multiple-terminal mode optical fiber
*1
(core/cladding diameter = 62.5 µm/125 µm)
Single-terminal mode optical fiber
(core/cladding diameter = 10 µm/125 µm)
SFP-LH (T) 1000BASE-LH Single-terminal mode optical fiber
(core/cladding diameter = 10 µm/125 µm)
Single-terminal mode (DSF) optical fiber
(core/cladding diameter = 8 µm/125 µm)
SFP-BX1U (T) 1000BASE-BX10-U Single-terminal mode optical fiber
(core/cladding diameter = 10 µm/125 µm)
LC simplex
connector
SFP-BX1D (T) 1000BASE-BX10-D
SFP-BX4U (T) 1000BASE-BX40-U
SFP-BX4D (T) 1000BASE-BX40-D