Instruction manual

2. Preparation for Installation
76
Table 2-5 General Installation Conditions for AX3640S Series Switches (Power Redundancy Models)
1/2
*1 Excluding the dimensions of connectors.
*2 Weight of the main device with two power supplies. However, the weights of cables, rack mounted brackets, memory cards and
transceivers are excluded.
*3 The power supply cable bundled with the main device is only applicable to 100 V AC.
Item
Model Name
AX3640S-24TW AX3640S-24T2XW AX3640S-48TW
PS-A01
mounted
PS-D01
mounted
PS-A01
mounted
PS-D01
mounted
PS-A01
mounted
PS-D01
mounted
Dimensions (W × D × H)
*1
445 × 440 × 43 mm
Weight
*2
9 kg or less
Input
voltage
Rating Single phase
100 to 120 V AC,
200 to 240 V
AC
*3
-48 V DC Single phase
100 to 120 V AC,
200 to 240 V
AC
*3
-48 V DC Single phase
100 to 120 V AC,
200 to 240 V
AC
*3
-48 V DC
Variation
range
90 to 127.2 V AC,
180 to 254.4 V
AC
-40 to -57 V DC
90 to 127.2 V AC,
180 to 254.4 V
AC
-40 to -57 V DC
90 to 127.2 V AC,
180 to 254.4 V
AC
-40 to -57 V DC
Frequency 50/60 ± 1 Hz - 50/60 ± 1 Hz - 50/60 ± 1 Hz -
Maximum input current 0.9 A
@ 100 V AC
1.6 A
@ -48 V DC
1.0 A
@ 100 V AC
1.9 A
@ -48 V DC
1.4 A
@ 100 V AC
2.7 A
@ -48 V DC
0.5 A
@ 200 V AC
- 0.5 A
@ 200 V AC
-0.7 A
@ 200 V AC
-
Maximum power
consumption
85 W 75 W 100 W 90 W 135 W 125 W
Maximum heat emission 306 kJ/h 270 kJ/h 360 kJ/h 324 kJ/h 486 kJ/h 450 kJ/h