Specifications
2. Installing a Switch
22
DC power cable (redundant power models (AX3630S and AX3640S series models))
Use the specified DC power cable. Using another power cable could result in a fire
or electric shock.
Connecting and disconnecting a DC power cable must be performed by a trained
technician or maintenance personnel.
Before connecting or disconnecting a DC power cable, turn off the power. Failure to
do so could result in a fire or electric shock.
NOTE
For details about the specifications for the specified power cable, see the
AX3800S/AX3600S/AX2400S Hardware Instruction Manual.
1. Connect the ground cable to the Switch.
Figure 2-11 Connecting the ground cable
(1) Screws (M4 x 8)
(2) Ground cable
(3) Ground terminal
Always connect the ground terminal for proper grounding. Failure to do so might not
only result in electric shock, but it might also introduce unwanted electrical noise that
could cause a switch failure.
NOTE
Ground cables are supplied with no cable end treatment on the power supply unit
side. Apply appropriate terminal treatment such as connecting terminals appropriate
for the power supply unit.
For details about ground cables, see the AX3800S/AX3600S/AX2400S Hardware
Instruction Manual.