Specifications

2. Installing a Switch
17
AC power cable (AC model and AC (PoE) model)
Connect the supplied power cable to the AC power connector on the rear of the Switch.
Figure 2-6 Connecting the AC power cable (for an AC model and an AC (PoE) model)
(1) Standby power connector (with a protection cap)
(2) Cable clamp
(3) AC power cable
(4) AC power connector
When using this switch at 100 V AC, use the supplied power cable. Using another
cable could result in a fire or electric shock.
In addition, do not use the supplied power cable with another switch. Doing so could
result in a fire or electric shock.
When using the switch at 200 V AC, use a power cable that satisfies the specified
specifications. Using another power cable could result in a fire or electric shock.
Always use a grounded outlet. Failure to do so might not only result in electric shock,
but it might also introduce unwanted electrical noise that could cause a switch
failure.
Do not remove the protection cap except to connect a cable. Using a switch with no
protection cap could result in a fire or electric shock.
CAUTION
Before connecting or disconnecting a power cable, use the power switch to turn the
Switch off.