Instruction manual

B. Physical Specifications of Network Interfaces
216
Item
Physical specifications
Transmission distance
2m to 100km
#2
2 m to 100 km
#1: When optical transmission loss is 16.0 dB or less, use an optical attenuator to adjust
the loss.
#2: For transmissions at 100-km distances, you must use optical fiber cables whose
dispersion characteristics are 20 ps/nm/km or less.
Table B-10 Physical specifications of 1000BASE-BX
Item
Physical specifications
Interface
1000BASE-BX10-
U
#1
1000BASE-BX10-
D
#1
1000BASE-BX40-
U
#2
1000BASE-BX40-
D
#2
Cable Type
Single-terminal mode
Core/cladding diameter
10 / 125m
Laser center wavelength
1.260 to 1.360m
1.480 to 1.500m
1.260 to 1.360m
1.480 to 1.500m
Receiving wavelength
1.480 to 1.500m
1.260 to 1.360m
1.480 to 1.500m
1.260 to 1.360m
Optical transmission
power (mean)
-9.0 to -3.0 dBm
-3.0 to 3.0 dBm
Optical reception power
(mean)
-19.5 to -3.0 dBm
-23.0 to -3.0 dBm
Optical transmission loss
(max.)
10.5 dBm
20.0 dBm
#3
Transmission distance
0.5 m to 10 km
0.5 m to 40 km
#1: 1000BASE-BX10-U and 1000BASE-BX10-D are paired to use.
#2: 1000BASE-BX40-U and 1000BASE-BX40-D are paired to use.
#3: When optical transmission loss is 6.0 dB or less, use an optical attenuator to adjust the
loss.
B.4 Ethernet 10GBASE-R interface
Table B-11 Physical specifications of 10GBASE-SR
Item
Physical specifications
Cable Type
Multiple-terminal mode
Core/cladding diameter
50 / 125m
62.5 / 125m
Transmission bandwidth
400
MHzkm
500
MHzkm
2000
MHzkm
160
MHzkm
200
MHzkm
Laser center wavelength
0.840 to 0.860m