Instruction manual

4. Installation of the Components
160
Figure 4-31 Attaching the standby power cable to the EPU
(1) Standby power connector (with protective cap)
(2) Standby power connector
(3) Standby power cable
Keep the protective cap in place, except when attaching the cable. Otherwise, a fire
or an electric shock might be caused.
NOTE
When one EPU supplies backup power to multiple devices, attach the standby
power cables to standby power connectors 2 and 3 and so on. In such cases,
remove each protective cap to connect the standby power cable. Store the
removed cap securely.
[Step 2]
Attach the standby power cable to the standby power connector on the back face of the
main device. Insert the connecter until you hear a click.
Figure 4-32 Attaching the standby power cable to the main unit
(1) Standby power cable
(2) Standby power connector (with protective cap)