Instruction manual
4. Installation of the Components
136
Figure 4-3 Attaching the rack mounting brackets (AX3800S)
(1) Rack mounting bracket – for the front surface (L)
(2) Rack mounting bracket – for the front surface (R)
(3) Rack mounting bracket – for the rear surface (L)
(4) Rack mounting bracket – for the rear surface (R)
(5) Rack mounting bracket – for attaching to the rear surface (L)
(6) Rack mounting bracket – for attaching to the rear surface (R)
(7) M4 x 6 screws (16)
(8) M3 x 8 screws (4)
NOTE
There are the following types of rack mounting brackets: for the front surface
(L)/(R), for the rear surface (L)/(R), and for attaching to the rear surface (L)/(R). The
left and right rack mounting brackets for the front surface are marked with "FL" and
"FR", respectively, and those for the rear surface are marked with "RL" and "RR".
The shapes of the right and left rack mounting brackets for attaching to the rear
surface are the same, and they are not identified by any markings.
NOTE
AX3800S series switches support the spacing of the front and rear of a rack pillar in
the range from 620 to 655, from 670 to 705, from 720 to 755, 770 to 805 and from
820 to 855 mm, by enabling to adjust the positions to which front and rear mounted
brackets are attached.
NOTE
If 100 mm of space for cables cannot be provided in front of the EPU, shift the rack
mounting brackets by 50 mm so that they protrude in the front, as shown in the
figure below.