Instruction manual

2. Preparation for Installation
101
#3: According to JIS Z 8813 Measuring Methods for Suspended Particulate Matter
Concentration in Air - General Requirements.
#4: If the temperature sensor for the intake air temperature exceeds 50 deg. C, the Switch
stops.
#5: No condensation
Table 2-11 Environmental conditions (redundant power models)
Item
Requirement
AX3630S, AX3640S
AX3650S
AX3830S
Quietness
-focused
settings
#1
Cooling-f
ocused
settings
#1
Quietness
-focused
settings
#1
Cooling-f
ocused
settings
#1
Quietness
-focused
settings
#1
Cooling-f
ocused
settings
#1
Noise
#2#3
25 deg. C
35 dB or
less
45 dB or
less
37 dB or
less
45 dB or
less
65 dB or
less
69 dB or
less
30 deg. C
35 deg. C
40 deg. C
45 dB or
less
45 dB or
less
69 dB or
less
50 deg. C
--
--
52 dB or
less
52 dB or
less
73 dB or
less
73 dB or
less
Vibration
2.45 m/s
2
or less
Dust
0.15 mg/m3 or less
#4
Temperatu
re
Operating
0 to 40 deg. C (23 to 28
deg. C recommended)
#5
-10 to 50 deg. C (23 to 28 deg. C recommended)
#6#7
Not
operating
-10 to 43 deg. C
-10 to 50 deg. C
Storage
and
transportati
on
-25 to 65 deg. C
Humidity
#8
Operating
10 to 85% (45 to 55%
recommended)
10 to 90% (45 to 55% recommended)
Not
operating
8 to 85%
8 to 90%
Storage
and
transportati
on
5 to 85%
5 to 90%
#1: The settings for the operating mode of the switch's fan.
#2: Measured value according to ISO 7779.