Instruction manual
2. Preparation for Installation
97
Item
Model name
AX3640S-24TW
AX3640S-24T2XW
AX3640S-48TW
PS-A01
mounted
PS-D01
mounted
PS-A01
mounted
PS-D01
mounted
PS-A01
mounted
PS-D01
mounted
0.5A
@ 200 V AC
--
0.5A
@ 200 V AC
--
0.7A
@ 200 V AC
--
Maximum power
consumption
85 W
75 W
100 W
90 W
135 W
125 W
Maximum heat
emission
306 kJ/h
270kJ/h
360 kJ/h
324 kJ/h
486 kJ/h
450kJ/h
#1: Excluding the dimensions of connectors.
#2: Weight of the main device with two power supplies. However, the weight of cables,
rack mounting brackets, memory cards and transceivers are excluded.
#3: The power cable bundled with the Switch is only applicable to 100 V AC.
Table 2-6 General installation conditions for AX3640S series switches (redundant power
models 2/2)
Item
Model name
AX3640S-48T2XW
AX3640S-24SW
AX3640S-24S2XW
PS-A01
mounted
PS-D01
mounted
PS-A01
mounted
PS-D01
mounted
PS-A01
mounted
PS-D01
mounted
Dimensions (W x D
x H)
#1
445 x 440 x 43 mm
Weight
#2
9 kg or less
Input
voltage
Rating
Single
phase
100 to 120
V AC,
200 to 240
V AC
#3
−48 V DC
Single
phase
100 to 120
V AC,
200 to 240
V AC
#3
−48 V DC
Single
phase
100 to 120
V AC,
200 to 240
V AC
#3
−48 V DC
Variatio
n range
AC
90 to
127.2V AC,
180 to
254.4V
DC
−40 to
−57V
AC
90 to
127.2V AC,
180 to
254.4V
DC
−40 to
−57V
AC
90 to
127.2V AC,
180 to
254.4V
DC
−40 to
−57V
Frequency
50/60 3Hz
--
50/60 3Hz
--
50/60 3Hz
--
Maximum input
current
1.5A
@ 100 V AC
2.9A
@ −48 V
DC
0.9A
@ 100 V AC
1.6A
@ −48 V
DC
1.0A
@ 100 V AC
1.9A
@ −48 V
DC