Troubleshooting guide

3. Troubleshooting Functional Failures During Operation
18
set-number-of-RADIUS-servers
If the time increases significantly, an application on a remote terminal, such as Telnet, might
have terminated due to a timeout. If this happens, change the RADIUS configuration
settings or the timeout setting of an application running on a remote terminal. In addition,
Telnet or FTP might have failed even when a message indicating successful RADIUS
authentication is output to the operation log. In this case, an application running on a
remote terminal might time out before it can connect to a running RADIUS server of those
you specified in the configuration. Change the settings so that a running RADIUS server
takes precedence, or decrease the value of response-timeout-value (in seconds) ×
number-of-resend-attempts.
3.2.4 Commands cannot be entered
Due to a failure or another reason, if the Switch is restarted, failure information about the
Switch is automatically collected (auto-log) two minutes after the restart. During this period,
it is not possible to enter a command. Wait a while and try again.
Note, however, that this problem does not occur when the
reload command is executed or
the Switch is turned on or off.