Specifications
system fan-control [AX1240S]
70
system fan-control [AX1240S]
Enables the cooling fan control functionality, which operates by monitoring the internal
temperature.
Syntax
To set information:
system fan-control
To delete information:
no system fan-control
Input mode
(config)
Parameters
None
Default behavior
The fan operates continuously.
Impact on communication
None
When the change is applied
The change is applied immediately after setting values are changed.
Note, however, that when the
no system fan-control command is executed, it might take
more than ten seconds for the change to be applied.
Notes
1. This command applies only to the AX1240S-48T2C model.
2. Even if this command is set, the cooling fan always operates for the first 10 minutes
after the Switch starts.
3. Operation when this command is set differs depending on the Switch model.
Table 7-1 Operation when system fan mode 2 (low-temperature setting) is set
Model Fan operation type
Behavior when the command is set
AX2230S-24T
AX1250S-24T2C
AX1240S-24T2C
Fanless Because these models do not have fans, this
command is invalid even if it is used.
AX1240S-48T2C Semi-fanless When the low-temperature setting is selected,
the system fan-control command setting
becomes invalid (fixed fan speed).
AX2230S-24P
AX1240S-24P2C
Fixed fan speed
Low-temperature operation is performed if this
command is omitted or the low-noise setting is
specified.