Specifications
schedule-power-control shutdown interface
62
schedule-power-control shutdown interface
Sets the port that shuts down while the scheduled power saving functionality is used.
Shutting down the port turns off the power, reducing the amount of power consumed.
Syntax
To set information:
schedule-power-control shutdown interface <IF# list>
To change information:
schedule-power-control shutdown interface [ add | remove ] <IF# list>
To delete information:
no schedule-power-control shutdown interface
Input mode
(config)
Parameters
interface <IF# list>
Specifies the port to be shut down in list format.
1. Default value when this parameter is omitted:
This parameter cannot be omitted.
2. Range of values:
For details about how to set <IF# list> and the specifiable values, see
Specifiable values for parameters.
interface add <IF# list>
Adds a port to be shut down to the list.
1. Default value when this parameter is omitted:
This parameter cannot be omitted.
2. Range of values:
For details about how to set <IF# list> and the specifiable values, see
Specifiable values for parameters.
interface remove <IF# list>
Removes a port to be shut down from the list.
1. Default value when this parameter is omitted:
This parameter cannot be omitted.
2. Range of values:
For details about how to set <IF# list> and the specifiable values, see
Specifiable values for parameters.
Default behavior
The operating status of a port is a state other than shutdown.
For details about port statuses, see the description of the
show port or show interfaces
operation command.