Specifications
schedule-power-control port cool-standby
59
schedule-power-control port cool-standby
Configures power saving operation for link-down ports during scheduled power saving
operation.
Syntax
To set information:
schedule-power-control port cool-standby
To delete information:
no schedule-power-control port cool-standby
Input mode
(config)
Parameters
None
Default behavior
Operation is at normal power consumption when the port is in the link-down state.
Impact on communication
Yes
When the change is applied
The change is applied immediately after setting values are changed.
Notes
1. If this command is set, link-up of the Fast Ethernet port takes about 3 seconds.
[AX1250S] [AX1240S]
2. This command sets the link status of all Fast Ethernet ports changes, which affects
communication. [AX1250S] [AX1240S]
3. The power saving functionality is disabled for Fast Ethernet ports that are set for
fixed speed or that have automatic MDIX functionality disabled. To enable the port
power saving functionality, enable auto-negotiation and the automatic MDIX
functionality (
mdix auto specified) during operation. [AX1250S] [AX1240S]
4. With the scheduled port power saving functionality enabled, at the scheduled time,
the link status of the Fast Ethernet ports changes in the same way as when using the
power-control port cool-standby command. If you do not want the link status to
change at the scheduled time due to the port power saving functionality, also specify
the
power-control port cool-standby command. [AX1250S] [AX1240S]
5. Because the power saving functionality of link-down ports is not supported for
1000BASE-X ports, no operation is performed even if this command is set.
Related commands
None