Specifications

system temperature-warning-level average
54
system temperature-warning-level average
Outputs an operation message when the average temperature during the specified period
exceeds the specified temperature.
Syntax
To set information:
system temperature-warning-level average [<temperature>] [ period
<days> ]
To delete information:
no system temperature-warning-level average
Input mode
(config)
Parameters
<temperature>
Sets the average temperature (in Celsius).
The temperature can be set in units of one degree Celsius.
1. Default value when this parameter is omitted:
For AX1250S-24T2C
43 (°C)
For AX2230S-24T, AX2230S-24P, AX1240S-24T2C, AX1240S-24P2C, and
AX1240S-48T2C
38 (°C)
2. Range of values:
For AX2230S-24P and AX1250S-24T2C
25 to 50 (°C)
For AX2230S-24T, AX1240S-24T2C, AX1240S-24P2C, and
AX1240S-48T2C
25 to 45 (°C)
period <days>
Sets the number of days to be used to calculate the average temperature.
1. Default value when this parameter is omitted:
30
2. Range of values:
1 to 30
Default behavior
An operation message is not output when the specified average temperature is exceeded.
Impact on communication