Specifications

system temperature-warning-level
52
system temperature-warning-level
Outputs a warning message when the intake temperature of the switch exceeds the
specified temperature.
Syntax
To set information:
system temperature-warning-level <temperature>
To delete information:
no system temperature-warning-level
Input mode
(config)
Parameters
<temperature>
Sets the temperature (in Celsius).
The temperature can be set in units of one degree Celsius.
1. Default value when this parameter is omitted:
This parameter cannot be omitted.
2. Range of values:
For AX2230S-24P and AX1250S-24T2C
25 to 50 (°C)
For AX2230S-24T, AX1240S-24T2C, AX1240S-24P2C, and
AX1240S-48T2C
25 to 45 (°C)
Default behavior
An operation message is not output when the specified temperature is exceeded.
Impact on communication
None
When the change is applied
The change is applied immediately after setting values are changed.
Notes
1. If the following operating environment conditions are not met, the log might be output
at a temperature lower than the specified intake temperature:
Provide sufficient ventilation to efficiently remove the heat from around the
Switches.
Do not stack Switches.
Do not install Switches vertically.
Do not place Switches near heat sources.
2. If the intake temperature of the Switch exceeds the specified temperature, an
operation message is immediately output.