Specifications

system fan mode
46
system fan mode
Sets the operating mode of the Switch fan.
Syntax
To set information:
system fan mode <mode>
To delete information:
no system fan mode
Input mode
(config)
Parameters
<mode>
Specifies operating mode 1 or 2 for the fan.
1: Low-noise setting
2: Low-temperature setting
1. Default value when this parameter is omitted:
This parameter cannot be omitted.
2. Range of values:
1 and 2
Default behavior
Operating mode 1 (Low-noise setting) is set.
Impact on communication
None
When the change is applied
The change is applied immediately after setting values are changed.
Notes
1. Operation when this command is set differs depending on the Switch model.
Table 6-1 Operation when system fan mode 2 (Low-temperature setting) is set
Model Fan operation type
Behavior when the command is set
AX2230S-24T
AX1250S-24T2C
AX1240S-24T2C
Fanless Because these models do not have fans,
this command is invalid even if it is used.
AX1240S-48T2C Semi-fanless When the low-temperature setting is
selected, the system fan-control
command setting is invalid (fixed fan
speed).