Specifications
36 Error Messages Displayed When Editing the Configuration
655
Message Description
system function isn't set. The setting is not possible because the system function
command has not been set.
Use the system function command to specify filter.
The sequence number exceeded the
maximum value. Try "resequence"
Command.
The automatic sequence number exceeds the maximum value.
Execute the resequence command.
This list cannot be set to this port. This access list cannot be applied to this Ethernet interface.
When an access list is applied to an Ethernet interface, the VLAN ID
of a flow detection condition in the access list must be included in the
settings of the Ethernet interface to which you want to apply the
access list.
This list cannot be set to VLAN. This access list cannot be applied to VLAN interfaces.
If the VLAN ID is set as a flow detection condition in an access list,
the access list cannot be applied to the VLAN interface. Apply it to
an Ethernet interface or delete the VLAN ID from the detection
condition.
This list name is being used as other
protocol type by other definition.
The identifier cannot be set because it is a name that has already
been used for another access list.
Specify a name that is not being used for another access list.
The maximum number of entries are
exceeded.
The number of specifiable entries was exceeded. Delete
unnecessary entries before executing the command.
36.1.18 QoS information
Table 36-18 QoS error messages
Message Description
Can not set command, because
limit-queue-length command is set.
A scheduling mode other than PQ cannot be set because the
limit-queue-length command is set.
Can not set command, because
scheduling modes is not PQ.
The limit-queue-length command cannot be set because a
scheduling mode other than PQ is set.
Can not set half duplex because
traffic-shape rate is specified for the port.
Duplex mode cannot be set because port bandwidth control is set for
the line.
Can not set half duplex because WFQ
min-rate is specified for the port.
Duplex mode cannot be set because the minimum guaranteed
bandwidth of WFQ mode is set for the line.
Can not set traffic-shape rate because of
the port is half duplex.
Port bandwidth control cannot be set because the line is half duplex.
Can not set WFQ min-rate because of
the port is half duplex.
The minimum guaranteed bandwidth of WFQ mode cannot be set
because the line is half duplex.