ethernet cfm cc alarm-start-time
578
ethernet cfm cc alarm-start-time
Sets the time after CC detects a failure until a trap is sent.
Syntax
To set or change information:
ethernet cfm cc level <Level> ma <No.> alarm-start-time <Time>
To delete information:
no ethernet cfm cc level <Level> ma <No.> alarm-start-time
Input mode
(config)
Parameters
level <Level>
Specifies the domain level that has been set by using the ethernet cfm domain
command.
1. Default value when this parameter is omitted:
This parameter cannot be omitted.
2. Range of values:
0 to 7
ma <No.>
Specifies an MA ID number that has been set by using the ma name command or the
ma vlan-group command. Even if the ma name command is used to specify the MA
name, using a character string, or a VLAN ID, this parameter specifies the MA ID
number.
1. Default value when this parameter is omitted:
This parameter cannot be omitted.
2. Range of values:
0 to 65535
alarm-start-time <Time>
Sets the time until a trap is sent following detection of a failure.
1. Default value when this parameter is omitted:
This parameter cannot be omitted.
2. Range of values:
Multiples of 100 from 2500 to 10000 in milliseconds
Default behavior
2500 milliseconds are used as the time until a trap is sent following detection of a failure.
Impact on communication
None
When the change is applied
The change is applied immediately after setting values are changed.