Specifications
power inline allocation [AX2200S] [AX1240S]
96
Port Setting range (in mW)
Increment (in mW)
0/5 to 0/24 4000 to 30000 200
<Threshold> [AX1240S]
Sets the amount of power for a port and the amount of power consumption to
be used for priority control in steps of 200 mW. This parameter becomes valid
when
limit is specified.
1. Default value when this parameter is omitted:
This parameter cannot be omitted.
2. Range of values:
4000 to 30000 (mW)
Default behavior
auto is set.
Impact on communication
Yes
When the change is applied
The change is applied immediately after setting values are changed.
Notes
1. When specifying manual allocation settings, read the documentation for the
power-receiving device. The customer performs the operation at the customer's own
risk.
2. Set a value for the maximum power consumption of the power-receiving device that
leaves a margin.
3. If a value smaller than the minimum power consumption required by the
power-receiving device is set manually, a power overload is detected and power to
the power-receiving device might stop. To restore power, execute the
activate
power inline operation command.
4. When you specify
limit for 0/1 to 0/4 ports, if you change the setting within the
range from 30000 (mW) to 60000 (mW) and select a value smaller than 30000 (mW)
before or after the setting change, the supply of the power to the applicable port
stops temporarily. [AX2200S]
Related commands
power inline