Specifications

power inline [AX2200S] [AX1240S]
93
power inline [AX2200S] [AX1240S]
Sets the port priority. Setting the power priority for each port ensures that power is supplied
to the appropriate ports.
Syntax
To set or change information:
power inline {critical | high | low | never}
To delete information:
no power inline
Input mode
(config-if)
Parameters
critical
Power is allocated to the most important port. Set this value for a port for which
power must always be supplied.
high
Power is supplied to ports whose priority is set to
high. If power becomes insufficient,
the supply of power to ports with this specification stops only after power to ports with
the
low setting has stopped.
low
Power is supplied to ports whose priority is set to
low. If power becomes insufficient,
the supply of power to ports with this specification stops before the supply of power
to ports with the
high setting.
never
Disables the PoE functionality of ports. When power is supplied, power is no longer
supplied and the PoE functionality is disabled. If a connected device is a
power-receiving device, power is not supplied.
Default behavior
high is set.
Impact on communication
None
When the change is applied
The change is applied immediately after setting values are changed.
Notes
1. This command can be set for models that support the PoE functionality.
2. If the remote device is a power supply device, set
never to disable the PoE
functionality of the line.
3. If a port has been shut down, no power is supplied to it.
4. If the
inactivate or activate operation command is executed, the supply of power
continues.
5. If you execute the
activate power inline operation command for a port with never